Deployment Guide

1054 Fabric OS Command Reference
53-1003131-01
slotPowerOn
2
slotPowerOn
Restores power to a slot.
SYNOPSIS slotpoweron slot
slotpoweron --help
DESCRIPTION Use this command to turn on the power to a blade unit. The slot must have a valid blade unit present and
the blade unit must be currently powered off. The slotShow command reports such slots as being in the
state of INSERTED, NOT POWERED ON.
Beginning with Fabric OS v7.3.0, this command is supported on Condor2 or Condor3 core blades also.
There is no frame loss when there are no ICLs connected.
NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS This command has the following operand:
slot
Specify the slot number of the blade to be powered on. This operand is required.
--help
Displays command usage.
EXAMPLES To power on blade unit 3:
switch:admin> slotpoweron 3
Powering on slot 3.
SEE ALSO slotPowerOff, slotShow