Deployment Guide

Fabric OS Command Reference 705
53-1003131-01
portCfg
2
To view the IPsec policy status for the Brocade 7840 switch:
switch:admin> portshow ipsec-policy all --ike
IPsec Policy OpStatus IKECnt Pre-Shared Key
IKE-ID OpStatus RefCnt Local IP Address Remote IP Address
-------------------------------------------------------------------------
myPolicy1 NotInUse 0 some test key
FUNCTION Configure tunnels, circuits, and management interfaces on the Brocade 7800 and Brocade 7840
switches and Brocade FX8-24 blade.
SYNOPSIS portcfg action [slot/]ve_port options arguments
DESCRIPTION Use this command to configure FCIP tunnels and FCIP circuits on the GbE/10GbE ports on the Brocade
7800 and Brocade 7840 switches, and FX8-24 platforms only and to configure the inband management
on these platforms. The FCIP tunnels on the local and remote GbE ports act as Virtual E_Ports
(VE_Ports) connecting the local and remote fabrics. The following operations can be performed with this
command:
portcfg fciptunnel - Create, modify, and delete Fibre Channel over IP (FCIP) tunnels.
- Configure a tunnel with the FCIP FastWrite feature.
- Enable or disable Tape Pipelining.
- Configure the compression options.
- Configure an IPsec-enabled tunnel.
- Configure VLAN tagging on the default FCIP circuit. This option is supported on Brocade 7800
switch and FX8-24 blade only.
- Configure Differentiated Services Code Point (DSCP) markings.
- Set the committed rate or minimum and maximum rates for the default circuit.
- Configure a tunnel for FICON emulation.
portcfg fcipcircuit - Create, modify, and delete additional FCIP circuits.
- Set or modify the committed rate or minimum and maximum rates for the circuit.
- Configure or change VLAN tagging on the default circuit.
- Set or modify additional circuit parameters.
portcfg mgmtif - Configure the inband management interfaces.
portcfg mgmtroute - Configure the routes for the inband management interfaces.
portcfg autoneg - Enable or disable autonegotiation settings for 1GbE ports.
NOTES You can configure up to 20 FCIP tunnels on the Brocade FX8-24 and up to 8 tunnels on the Brocade
7800.
OPERANDS This command has the following operands:
slot
For bladed systems only, specifies the slot number of the port to be configured,
followed by a slash (/).
ve_port
Specifies the number of the VE_Port associated with the tunnel configured on one
of the GbE/10GbE ports to be configured. The VE_Ports are numbered 16-23 on
the Brocade 7800.
fciptunnel