Users Guide

Fabric OS Administrator’s Guide 147
53-1002920-02
Buffer credit recovery
5
Buffer credit recovery is enabled automatically across any long-distance connection for which the
E_Port, F_Port, or EX_Port buffer credit recovery mechanism is supported. For 16-Gbps FC devices
and blades (Brocade 6505, 6510, 6520, M6505, 6547, CR16-4, CR16-8, FC8-32E, FC8-48E,
FC16-32, FC16-48), you can use the portCfgCreditRecovery command to disable or enable buffer
credit recovery on a port.
Buffer credit recovery over an E_Port
To support buffer credit recovery, E_Ports must be connected between devices that support 16
Gbps or between devices that support 8 Gbps.
Devices that support 16 Gbps:
- Brocade 6505, 6510, 6520, M6505, 6547
- FC8-32E, FC8-48E,FC16-32, FC16-48
Devices that support 8 Gbps:
- Brocade 300, 5100, 5300, 5410, 5424, 5450, 5480, VA-40FC
- FC8-16, FC8-32, FC8-48
If a device that supports 16 Gbps is connected to a device that supports only 8 Gbps, buffer credit
recovery is disabled, even if both devices are running 8 Gbps.
The buffer credit recovery feature for E_Ports is enabled for the following flow-control modes:
Normal (R_RDY)
Virtual Channel (VC_RDY)
Extended VC (EXT_VC_RDY)
Buffer credit recovery over an F_Port
Buffer credit recovery for F_Ports is supported for F_Port-to-N_Port links between a Brocade switch
and Access Gateway, between a Brocade switch and an adapter, and between an Access Gateway
and an adapter. For an F_Port on a Brocade switch connected to an Access Gateway, the following
conditions must be met:
Both devices must run Fabric OS v7.1 or later.
Fabric OS must support buffer credit recovery at either end of the link.
If both devices support 16 Gbps, the flow-control mode can be either Normal mode (R_RDY) or
VC mode (VC_RDY); otherwise the flow-control mode must be R_RDY.
For an F_Port on a Brocade switch or Access Gateway connected to an adapter, the following
conditions must be met:
The Brocade switch or Access Gateway must run Fabric OS v7.1 or later.
Fabric OS must support buffer credit recovery at both ends of the link.
The adapter must be running HBA v3.2 firmware or later.
The adapter must operate at maximum speed.
The flow-control mode must be R_RDY.
The feature is enabled automatically during a link reset if the conditions are met. If the conditions
for buffer credit recovery are not met, the link will come up, but buffer credit recovery will not be
enabled.