Users Guide

78 Fabric OS Command Reference
53-1002921-02
bottleneckMon
2
bottleneckMon
Monitors and reports latency and congestion bottlenecks on F_Ports and E_Ports.
SYNOPSIS bottleneckmon --enable [-cthresh congestion_threshold]
[-lthresh latency_threshold] [-time seconds]
[-qtime seconds] [-alert | -alert=congestion |
-alert=latency | -noalert]
[-lsubsectimethresh time_threshold]
[-lsubsecsevthresh severity_threshold]
bottleneckmon --disable
bottleneckmon --config [-cthresh congestion_threshold]
[-lthresh latency_threshold][-time seconds]
[-qtime seconds] [-alert | -alert=congestion |
-alert=latency | -noalert]
[-lsubsectimethresh time_threshold]
[-lsubsecsevthresh severity_threshold]
[[slot/]port_list]
bottleneckmon --configclear [slot/]port_list
bottleneckmon --exclude [slot/]port_list
bottleneckmon --include [slot/]
port_list
bottleneckmon --show [-interval seconds] [-span seconds]
[-refresh][-congestion | -latency] [[slot/]port | '*']
bottleneckmon --status
bottleneckmon --cfgcredittools -intport -recover
[off | onLrOnly | onLrThresh] [-lrthresh threshold]
-fault [edgeblade | coreblade | edgecoreblade]
bottleneckmon --cfgcredittools -intport -check slot/blade_port,VC
bottleneckmon --linkreset slot/blade_port
bottleneckmon --showcredittools
bottleneckmon --help
DESCRIPTION Use this command to (1) detect latency and congestion bottlenecks on F[L]_Ports and E_Ports and (2) to
manage credit recovery on backend ports. Bottleneck detection and credit recovery are two independent
functions; enabling credit recovery has no impact on bottleneck detection and vice versa.
Bottleneck Detection
For bottleneck detection, this command provides the following management functions:
Enabling or disabling bottleneck detection on a switch and optionally configuring thresholds and alert
parameters.
Changing alert parameters on specified ports after you have enabled the feature on the switch.