Users Guide

Fabric OS Message Reference 757
53-1002929-01
SEC-1192
5
SEC-1192
Message Security violation: Login failure attempt via <connection method>.
Message Type LOG
Severity INFO
Probable Cause Indicates a serial or modem login security violation was reported. The wrong password was used while
trying to log in through a serial or modem connection; the login failed.
Recommended
Action
Use the correct password.
SEC-1193
Message Security violation: Login failure attempt via <connection method>. IP Addr: <IP
address>.
Message Type LOG
Severity INFO
Probable Cause Indicates a specified login security violation was reported. The wrong password was used while trying to
log in through the specified connection method; the login failed.
Recommended
Action
The error message lists the violating IP address. Verify that this IP address is being used by a valid
switch admin. Use the correct password.
SEC-1194
Message This switch does not have all the required PKI objects correctly installed.
Message Type LOG
Severity WARNING
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.