Deployment Guide

Table Of Contents
Fabric OS Message Reference 205
53-1003140-01
C2-1006
5
C2-1006
Message S<slot number>,C<chip index>: Internal link errors reported, no hardware faults
identified, continuing monitoring: fault1:0x<fault1_cnt>, fault2:0x<fault2_cnt>
thresh1:0x<threshold_used>.
Message Type LOG
Severity WARNING
Probable Cause Indicates that some internal link errors have been detected. These errors can be normal in an active
running system.
The system automatically starts a more detailed monitoring of the errors reported in the internal
hardware. There is no action required by the user at this time. If any actual hardware failures are
detected, the C2-1010 message will be generated identifying the failing field-replaceable unit (FRU).
Recommended
Action
No action is required.
C2-1007
Message S<slot number>,P<port number>(<blade port number>): best effort QoS will be turned
off at next port state change as it is not supported under this configuration
Message Type LOG
Severity WARNING
Probable Cause Indicates that quality of service (QoS) will be turned off automatically at the next port state change
because best effort QoS is no longer supported on 4 Gbps or 8 Gbps platform long distance ports.
Recommended
Action
No action is required.
C2-1008
Message S<slot number>,P<port number>(<blade port number>): QoS overwrites
portcfglongdistance vc_translation_link_init. ARB will be used on the link.
Message Type LOG
Severity WARNING
Probable Cause Indicates that quality of service (QoS) has overwritten the fill word IDLE used on the long distance links.
Arbitrated loop (ARB) will be used on the link.
Recommended
Action
No action is required.