Deployment Guide

Table Of Contents
Fabric OS Message Reference 437
53-1003140-01
FICN-1079
5
FICN-1079
Message DevTapeEgr:ReadBlkReport:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>:Emuls=0x<the number of idle
state to non-idle state transitions while this tape was loaded>:Cmds=0x<the number
of emulated host read commands processed while this tape was loaded>:Chains=0x<the
number of emulated host chains processed while this tape was loaded>:MBytes=<the
number of emulated read Kilobytes processed while this tape was loaded>.
Message Type LOG
Severity INFO
Probable Cause Indicates a Rewind and Unload I/O has been processed from a remotely connected Logical Partition
(LPAR) and Read Block pipelining was performed on the currently loaded tape.
Recommended
Action
No action is required.
FICN-1080
Message DevTapeEgr:ReadCpReport:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>:Emuls=0x<the number of idle
state to non-idle state transitions while this tape was loaded>:Cmds=0x<the number
of emulated host read commands processed while this tape was loaded>:Chains=0x<the
number of emulated host chains processed while this tape was loaded>:MBytes=<the
number of emulated read Kilobytes processed while this tape was loaded>.
Message Type LOG
Severity INFO
Probable Cause Indicates a Rewind and Unload I/O has been processed from a remotely connected Logical Partition
(LPAR) and Read Channel Program pipelining was performed on the currently loaded tape.
Recommended
Action
No action is required.
FICN-1081
Message DevTapeIng:LRJ received on Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr> lastCmds=0x<Last 4 commands
received from the channel for this device> lastStatus=0x<Last 4 status values
presented to the channel for this device> treating as system reset event.
Message Type LOG
Severity WARNING
Probable Cause Indicates a Link Level Reject (LRJ) from a FICON channel indicates that the channel does not have a
path established to the Control Unit.