Deployment Guide

Table Of Contents
586 Fabric OS Message Reference
53-1003140-01
HAM-1006
5
HAM-1006
Message EMAC controller for Active CP is BAD.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the local Ethernet Media Access Controller (EMAC) on the active CP has been marked
BAD as determined by the diagnostic test run by the high availability manager (HAM) module.
Recommended
Action
The standby CP will take over and reset the active CP. The system will be non-redundant because the
standby CP becomes the active CP.
HAM-1007
Message Need to reboot the system for recovery, reason: <reason name>.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the switch in current condition needs to be restarted to achieve a reliable recovery. The
reasons can be one of the following:
The standby CP was not ready when failover occurred.
The failover occurred when the last logical switch (LS) transaction was incomplete.
The switch failed when timeout occurred at certain stage.
The cold or warm recovery has failed.
Recommended
Action
If auto-reboot is enabled, the switch will automatically restart. Otherwise, execute the reboot command
to manually restart the switch.
HAM-1008
Message Rebooting the system for recovery - auto-reboot is enabled.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the recovery by auto-reboot is enabled, and therefore the switch automatically restarts.
This message is displayed if the event logged in HAM-1007 has occurred and auto-reboot is enabled.
Recommended
Action
Wait until the switch is up to perform any operations.