Deployment Guide

Table Of Contents
712 Fabric OS Message Reference
53-1003140-01
PLAT-1009
5
PLAT-1009
Message BladeSystem Chassis type requires setting maximum internal port speed to 8Gbps.
Message Type LOG
Severity WARNING
Probable Cause Indicates that the chassis has an older midplane that cannot support 16 GFC internal ports.
This message occurs only on the Brocade 6548.
Recommended
Action
Install the switch in a newer chassis.
PLAT-1072
Message The chassis is disabled because no Core Blades are available. Insert/replace one
or both Core Blades and run chassisenable.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the chassis has been disabled because of the unavailability of the core blades. There must
be at least one core blade in enabled state for the chassis to be considered ready. All core blades are
either missing, faulted, or powered off. This results in all logical switches (and ports) being disabled.
Recommended
Action
Make sure that all core blade slots have core blades inserted and their ejector switches are closed.
Power on core blades that are powered off, and power cycle or replace the core blades that are faulted.
Run the chassisenable command to re-enable the ports.
Running the fastboot or reboot command will also result in enabling the logical switches and ports.