Hardware Reference Manual

38 Brocade M6505 16 Gbps Fibre Channel SAN I/O Module Hardware Reference Manual
53-1002576-02
Removing and replacing SAN I/O Modules
4
For added convenience, you can refer to Figure 7, which provides the generic process for
removing an SFP+ transceiver from a port.
FIGURE 7 Removing an SFP+ transceiver from a port
4. Disconnect the RJ-45 Ethernet cable from the COM serial port.
5. Press the release latch to free the release lever. Refer to Figure 3 on page 13.
6. Gently pull the release lever down and toward you to release the SAN I/O Module.
You will feel the SAN I/O Module unseat and move out of the I/O module bay approximately
0.6
cm (0.25 inch).
7. Slide the SAN I/O Module out of the I/O module bay and set it aside.
8. Insert the replacement SAN I/O Module in the I/O module bay of the Dell M1000e Blade
Server Enclosure. You must complete this step within 60
seconds.
ATTENTION
If you are not inserting a replacement SAN I/O Module in the I/O module bay, use a filler panel
to fill the empty slot to maintain proper air flow and cooling. Do not leave the slot empty.
9. Reinsert the SFP+ transceivers that you removed in step 3.