Messages Reference Guide

Fabric OS Message Reference 163
53-1002749-01
BL-1000
5
BL Messages
BL-1000
Message Initializing ports...
Message Type LOG
Severity INFO
Probable Cause Indicates that the switch has started initializing the ports.
Recommended
Action
No action is required.
BL-1001
Message Port initialization completed.
Message Type LOG
Severity INFO
Probable Cause Indicates that the switch has completed initializing the ports.
Recommended
Action
No action is required.
BL-1002
Message Init Failed: slot <slot number> DISABLED because internal ports were not ONLINE,
<list of internal port number not ONLINE>.
Message Type FFDC | LOG
Severity CRITICAL
Probable Cause Indicates that the blade initiation failed because one or more of the internal ports was not online. The
blade is faulted.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
Additional blade fault messages precede and follow this error, providing more information. Refer to other
error messages for recommended action.
If the message persists, replace the blade.