BL-1022
5
BL-1022
Message Init Failed: Switch DISABLED because internal ports were not ONLINE, <list of
internal port number not ONLINE>.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that the switch initiation failed because one or more of the internal ports was not online. The
switch is faulted.
Recommended
Action
Reboot or power cycle the switch.
Additional fault messages precede and follow this error providing more information. Refer to other error
messages for recommended action.
If the message persists, replace the switch.
BL-1023
Message Blade in slot <slot number> was reset before blade init completed. As a result the
blade is faulted.
Message Type LOG
Severity CRITICAL
Probable Cause Indicates that the blade was reset before the initialization completed.
Recommended
Action
Reboot or power cycle the blade using the slotPowerOff and slotPowerOn commands.
If the message persists, replace the blade.
BL-1024
Message All ports on the blade in slot <slot number> will be reset as part of the firmware
upgrade.
Message Type LOG
Severity INFO
Probable Cause Indicates that a recent firmware upgrade caused the blade firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all datapath elements were reset.
Recommended
Action
No action is required.