Messages Reference Guide

694 Fabric OS Message Reference
53-1002749-01
SEC-1031
5
SEC-1031
Message Current security policy DB cannot be supported by standby. CPs will go out of
sync.
Message Type LOG
Severity WARNING
Probable Cause Indicates the security database size is not supported by the standby control processor (CP).
Recommended
Action
Reduce the security policy size by deleting entries within a policy or by deleting some policies.
SEC-1032
Message Empty FCS list is not allowed.
Message Type LOG
Severity ERROR
Probable Cause Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1033
Message Invalid character used in member parameter to add switch to SCC policy; command
terminated.
Message Type LOG
Severity ERROR
Probable Cause Indicates a member parameter in the secPolicyAdd command is invalid (for example, it may include an
invalid character, such as an asterisk). A valid switch identifier (a WWN, a domain ID, or a switch name)
must be provided as a member parameter in the secPolicyAdd command. Only the secPolicyCreate
command supports use of the asterisk for adding switches to policies.
Recommended
Action
Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name) to
add specific switches to the Switch Connection Control (SCC) policy.