fcFeOp group
4
fcFxPortID
1.3.6.1.3.42.2.1.2.1.1.3
Read only The address identifier by which this Fx_Port is identified within the
fabric. The Fx_Port might assign its address identifier to its attached
Nx_Ports during fabric login.
fcFPortAttachedPortName
1.3.6.1.3.42.2.1.2.1.1.4
Read only The port name of the attached N_Port, if applicable. If the value of this
object is ‘0000000000000000’H, this Fx_Port has no Nx_Port
attached to it. This variable has been deprecated and might be
implemented for backward compatibility.
fcFPortConnectedPort
1.3.6.1.3.42.2.1.2.1.1.5
Read only The address identifier of the destination Fx_Port with which this Fx_Port
is currently engaged in either a Class 1 or loop connection. If the value
of this object is ‘000000’H, this Fx_Port is not engaged in a connection.
This variable has been deprecated and might be implemented for
backward compatibility.
fcFxPortBbCreditAvailable
1.3.6.1.3.42.2.1.2.1.1.6
Read only The number of buffers currently available for receiving frames from the
attached port in the buffer-to-buffer flow control. The value should be
less than or equal to fcFxPortBbCredit.
fcFxPortOperMode
1.3.6.1.3.42.2.1.2.1.1.7
Read only The current operational mode of the Fx_Port.
fcFxPortAdminMode
1.3.6.1.3.42.2.1.2.1.1.8
Read only The desired operational mode of the Fx_Port.
fcFxPortPhysTable
1.3.6.1.3.42.2.1.2.3
Not
accessible
A table that contains, one entry for each Fx_Port in the fabric element,
physical level status and parameters of the Fx_Ports.
fcFxPortPhysEntry
1.3.6.1.3.42.2.1.2.3.1
Not
accessible
An entry containing physical level status and parameters of an Fx_Port.
fcFxPortPhysModuleIndex
1.3.6.1.3.42.2.1.2.3.1.1
Read only Identifies the module containing the Fx_Port for which this entry
contains information.
fcFxPortPhysFxPortIndex
1.3.6.1.3.42.2.1.2.3.1.2
Read only Identifies the Fx_Port within the module. This number ranges from 1 to
the value of fcFeModulePortCapacity for the associated module. The
value remains constant for the identified Fx_Port until the module is
re-initialized.
fcFxPortPhysAdminStatus
1.3.6.1.3.42.2.1.2.3.1.3
Read only The desired state of the Fx_Port:
online (1) Place port online
offline (2) Take port offline
testing (3) Initiate test procedures
A management station might place the Fx_Port in a desired state by
setting this object accordingly. The testing state (3) indicates that no
operational frames can be passed. When a fabric element initializes, all
Fx_Ports start with fcFxPortPhysAdminStatus in the offline state (2). As
the result of either explicit management action or per configuration
information accessible by the fabric element, fcFxPortPhysAdminStatus
is then changed to either the online (1) or testing (3) states or remains
in the offline state (2).