Using the CMC GUI to set the IP address
To modify the SAN I/O Module IP address using the CMC GUI, perform the following steps:
1. Select I/O Module
Overview from the left navigation panel.
2. Click the Se
tup tab.
3. Enter the new information in the IP A
ddress, Subnet Mask, and Gateway fields as appropriate,
then click Apply.
4. To enable DHCP, select DHCP Enabled, then click Apply.
Refer to the Dell PowerEdge M1000e Enclosure Owner’s Manual that comes with your Dell
M1000e Blade Server Enclosure for more information.
Using the CMC CLI to set the IP address
To modify the SAN I/O Module IP address through the Chassis Management Controller (CMC) CLI,
perform the following steps:
1. Establish a Telnet session to the CMC CLI.
2. At the command prompt, enter co
nnect switch-x where x is the bay in which the SAN I/O
Module is installed. For example, switch-x can be one of the following values:
Switch-3 for SAN I/O Module installed in bay B1.
Switch-4 for SAN I/O Module installed in bay B2.
Switch-5 for SAN I/O Module installed in bay C1.
Switch-6 for SAN I/O Module installed in bay C2.
3. Log in to the default administrative ac
count using the following default settings:
Login: admin
Password: pa
ssword