Release Notes

Closed defects with code change in Fabric OS v7.2.0
Fabric OS v7.2.0a Release Notes v1.0 Page 84 of 93
Defect ID:
DEFECT000455717
Technical Severity:
High
Summary:
Request for message to be generated when the TKLM key vault comes back online successfully
Symptom:
Upon recovering the TKLM key vault and its successful re-connection, no message is generated
indicating the event (cryptocfg --show -groupcfg verified that it was connected).
Workaround:
Use cryptocfg --show -groupcfg
Risk of Fix:
Low
Probability:
Medium
Feature:
Data Security
Function:
Encryption Group
Reported In Release:
FOS7.1.0
Defect ID:
DEFECT000456392
Technical Severity:
Medium
Summary:
Number of headings in fwportdetailshow is one greater than the number of fields below
Symptom:
fwportdetailshow output has more heading than data, LR data is not displayed under LR heading.
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
System Performance
Reported In Release:
FOS7.0.2
Service Request ID:
1162772
Defect ID:
DEFECT000456440
Technical Severity:
Medium
Summary:
Severity level discrepancy between raslog and snmp for FW-1404 and FW-1406 events
Symptom:
During memory usage testing, customer noticed Inconsistent severity level between the error log and
SNMP for FW-1404 and FW-1406 events.
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
SNMP
Reported In Release:
FOS7.0.2
Service Request ID:
1168970/P1167804
Defect ID:
DEFECT000457972
Technical Severity:
High
Summary:
After an FCIP circuit bounce, invalid buffers index messages are reported on the console.
Symptom:
After an FCIP tunnel bounces due to a network issue, error messages are generated on console and
the TCP connections making up the tunnel/circuit aborts instead of closing gracefully.
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
FCIP
Reported In Release:
FOS7.0.0
Service Request ID:
1171473
Defect ID:
DEFECT000458751
Technical Severity:
Medium
Summary:
FC ports shown as inactive by ITE
Symptom:
FC ports from Brocade switch as shown as inactive by embedded platform switchshow.
Risk of Fix:
Low
Probability:
Low
Feature:
Embedded Platform Services
Function:
Other
Reported In Release:
FOS7.0.0_pha
Defect ID:
DEFECT000459102
Technical Severity:
High
Summary:
Domain change caused proxy devices stuck in "initializing" state
Symptom:
Proxy devices stuck in "initializing" state after adding new switch to edge fabric
Risk of Fix:
Medium
Probability:
Low
Feature:
FOS Software
Function:
FCR
Reported In Release:
FOS7.0.2
Service Request ID:
1172345