Installation and Service Manual
Table Of Contents
- Dell EMC PowerEdge T150 Installation and Service Manual
- Contents
- About this document
- PowerEdge T150 system overview
- Initial system setup and configuration
- Minimum to POST and system management configuration validation
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- System cover
- Frontbezel
- Drives
- Removing a 3.5-inch drive carrier from the drive bay
- Installing a 3.5-inch drive carrier into the drive bay
- Removing a drive from the drive carrier
- Installing a drive into the drive carrier
- Removing a 2.5-inch drive from the 3.5-inch drive adapter
- Installing a 2.5-inch drive into the 3.5-inch drive adapter
- Removing a 3.5-inch drive adapter from a 3.5-inch drive carrier
- Installing a 3.5-inch adapter into a 3.5-inch drive carrier
- Setting the cooling fan speed for 8 TB drives
- Cable routing
- Optional optical drive
- System memory
- Cooling fans
- Internal USB memory key
- Expansion cards
- Optional BOSS S1 card
- Processor and heat sink
- Power supply unit
- System battery
- Intrusion switch
- System board
- Trusted Platform Module
- Control panel
- Jumpers and connectors
- System diagnostics and indicator codes
- Getting help
- Documentation resources
Next steps
1. Follow the procedure listed in After working inside your system.
2. While booting, press F2 to enter System Setup and verify that the system detects the USB memory key.
Expansion cards
NOTE: When an expansion card is not supported or missing, the iDRAC and Lifecycle Controller logs an event. This does
not prevent your system from booting. However, if a F1/F2 pause occurs with an error message, see Troubleshooting
expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/poweredgemanuals.
Expansion card installation guidelines
Figure 36. Expansion card slot connectors
1.
Slot 1 2. Slot 2
3. Slot 3 4. Slot 4
Table 15. Expansion card slots supported on the system board
PCIe slot Processor connection PCIe slot height PCIe slot length Slot width
Slot 1 (Gen4 from
processor)
Processor Full height Half length
x4 link in x8 slot
Slot 2 (Gen4 from
processor)
Processor Full height Half length
x16 link in x16 slot
Slot 3 (Gen3) Platform Controller Hub Full height Half length x1
Slot 4 (Gen3) Platform Controller Hub Full height Half length x4 link in x8 slot
Installing and removing system components 47