Specifications

8 Installing the Hardware
Installing Power Modules
CAUTION: Do not install the Power Supply 1200W-AC and Power Supply
1600W-AC in the same chassis. The line cards will power down and data may
be lost.
If there is a failure in the power supply, you must replace it. Power supplies are
not field serviceable.
The C7004/C150 has six power supply slots at the front-bottom of the chassis.
The C7008/C300 has eight power supply slots at the front-bottom of the chassis.
The slots accept either the 1200W or 1600W AC power supply units (PSUs).
AC Power Supplies
There are two types of power supplies: Power Supply 1200W-AC and Power
Supply 1600W-AC. The minimum and redundant power supplies required to
operate are listed in the table below. Dell Networking recommends the
redundancy configuration.
The following table lists the PSU requirements for Dell Networking OS
version 8.4.5.0 or prior. 1600W-AC PSU is recognized by version 8.4.5.0 or
later.
Voltage Minimum
PSUs
Minimum with
Redundant
PSUs
C7004/C150 Power Supply 1200W-
AC/Power Supply
1600W-AC
100-120 Configuration
Dependent
Configuration
Dependent
200-240 Configuration
Dependent
Configuration
Dependent
C7008/C300 Power Supply 1200W-
AC/Power Supply
1600W-AC
100-120 Configuration
Dependent
Configuration
Dependent
Power Supply 1200W-AC 200-240 Configuration
Dependent
Configuration
Dependent
Power Supply 1600W-AC 200-240 Configuration
Dependent
Configuration
Dependent