Users Guide

Platform Version Size ReleaseTime
C-Series:C1048P 9.9(0.0) 27132051 Sep 4 2015 09:59:54
PE BOOT IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target Checksum
boot flash 3.3.1.7 Control Processor passed
PE FPGA IMAGE INFORMATION :
---------------------------------------------------------------------
FPGA Name Version
CPLD 16
PE PoE-CONTROLLER IMAGE INFORMATION
---------------------------------------------------------------------
Type Version
PoE Controller 2.65
De-provisioning a Port Extender
To remove the provisioned configuration from a PE, follow one of the de-provisioning procedures in this
section.
To de-provision a PE that is online, shut down its cascade ports and then enter the no pe
provision pe-id command; for example:
Dell(conf)# interface range te 1/0 , te 1/12
Dell(conf-if-range-te-1/0,te-1/12)# shutdown
Dell(conf-if-range-te-1/0,te-1/12)# exit
Dell(conf)# no pe provision 10
To de-provision a PE that is offline, enter the no pe pe-id command; for example:
Dell(conf)# no pe 10
To de-provision all attached PEs, disable the extended-bridge feature on the parent C9010. All
attached PEs (online and offline) are brought down. All PE configurations are removed. For example:
Dell(conf)# no feature extended-bridge
This command will disable the Extended-Bridge feature which will bring down
all the PEs and remove all the PE configs.
Proceed with Extended-Bridge feature disable? [yes/no]:yes
Troubleshooting a Port Extender
Normally you manage a PE through the C9010 console attached to the parent C9010 switch. However, if
a port extender cannot connect to the C9010, use the following commands from a PE console to
troubleshoot the error condition.
cd Change current directory
clear Reset functions
copy Copy from one file to another
delete Delete a file
diag Run diagnosis
dir List files on a filesystem
disable Turn off privileged commands
enable Turn on privileged commands
exit Exit from the EXEC
format Format a filesystem
hostname Set system's network name
no Reset a command
offline Take a PE stack unit offline
online Bring a PE stack unit online
power-cycle Power-cycle the unit(s)
Port Extenders (PEs)
781