Administrator Guide

power inline restore pe pe-id stack-unit unit-number
pe pe-id — Specify the port extender ID. The range is from 0 to 255.
stack-unit unit-number — Specify the stack unit number of the port extender. The range is from 0 to 7.
Example of Restoring Power Delivery on the Port Extender
The following example disable power delivery on the port extender.
Dell#power inline restore pe 0 stack-unit 0
Example of Displaying Restored Power Delivery on the Port Extender
Dell#show power inline pe 0 stack-unit 0
Global inline power Threshold: 99
Power Reserved for inline Power:841W
Total Inline Power Consumed: 0W
Remaining inline power Available:841W
Power Management Mode: Static
Interface Inline Power Inline Power Class Device PoE Port LLDP
Max / Alloc Consumed Type Priority Support
(Watts) (Watts)
----------------------- ------------ ------- ------ -------- ------
PeGi 0/0/0 30.00/0.00 0.00 NO_PD - critical 0
Monitor the Power Budget
The power budget is the amount of power available from the installed PSUs minus the power required to operate the port extender.
To help determine if power is available for additional PoE or PoE+ ports, use the show power inline and show power detail
commands. For information about these commands, see Displaying PoE Power Allocation.
The C1048P PE has one 1000 W fixed PSU and one external power supply with a capacity of 1000 W. The power required for system
components is 150 W. The power available for PoE or PoE+ is calculated after excluding the power needed for system components and
power redundancy.
The following table defines the power budgeting for PE. In this table, 150 W from the fixed PSU and EPS are reserved for system power
and redundancy. The remaining 850 W from each PSU is allotted for PoE or PoE+.
Table 73. Power Budgeting for the PE
PoE or PoE+
Power Budget
Limit
Model Name Maximum PSU
Output Ability
(1 PSU)
Maximum PSUs
Output Ability
(2 PSUs)
System Power
Consumed
Redundancy
Power
Consumed
Threshold Max In-line
Power Available
C1048P 1000 W internal
PSU
Upto 2000 W 150 W 150 W 99% 1683 W
N2024P 1000 W internal
PSU
Upto 2000 W 150 W 150 W 99% 1683 W
N2048P 1000 W internal
PSU
Upto 2000 W 150 W 150 W 99% 1683 W
N3024P 715 W FRU power
supplies by
default. Supports
up to two 1100 W
PSUs.
Upto 2200 W 150 W 150 W 99% 1881 W
N3048P 1100 W FRU
power supplies by
Upto 2200 W 150 W 150 W 99% 1881 W
Power over Ethernet (PoE) 729