Concept Guide

ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 10
Status: online
System Mac: 00:01:02:03:11:01
PE Up Time: 00:01:22
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/12(A)
Cascade LAG: Po 268(Up)
------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
------------------------------------------------------------------------
0 online - C1048P 00:01:02:03:11:01 52
Dell#show interfaces port-channel 268 brief
Codes: L - LACP Port-channel
O - OpenFlow Controller Port-channel
A - Auto Port-channel
I - Internally Lagged
LAG Mode Status Uptime Ports
A 268 N/A up 00:01:54 Te 1/12 (Up)
In a dual-homing setup, the primary system selects PE with a PE ID based on any of the above scenarios. The secondary system gets
the PE ID selected by the primary and enables the ports connected only to the PE.
Managing a Port Extender
Manage the PEs connected to a parent C9010 through a Telnet session. You can display PE operational status and current stack
conguration or rest the PE.
Starting a Telnet Session
To manage a standalone port extender or a PE stack, start a Telnet session with the PE or the master unit in the stack using the connect
pe command.
connect pe pe-id
EXEC Privilege
pe-id is a port-extender ID number from 0 to 255.
Dell# connect pe 254
Login: peadmin
Password: calvin
Displaying PE Status
To verify the operational status of a port extender attached to a C9010, enter any of the show commands in this section.
In the command output, online indicates that a port extender is up; offline indicates that a port extender is down.
Dell#show pe 255 brief
-- Port Extenders Information --
---------------------------------------------------------------------------------------
PE-id Status Stack-size Type System-MAC Description
---------------------------------------------------------------------------------------
255 online 2 N3048-PE f8:b1:56:33:ee:f2
Dell#show pe 1
Maximum number of PE Units allowed: 80
Current number of PE units in the system: 80 (Online: 0 Offline: 80)
Current number of PEs in the system: 15 (Online: 0 Offline: 15)
Port Extenders (PEs)
761