Administrator Guide

Online Insertion and Removal
You can add, replace, or remove chassis components (RPMs, line cards, fan modules, power supplies) while the switch is operating. C9010
RPMs and line cards are hot-swappable. Use the information in this section when inserting an RPM or line card in the C9010 chassis. For
more information about how to install an RPM or line card in the C9010, see the C9010 Getting Started Guide or C9010 Installation Guide.
RPM Online Insertion
Dell Networking systems can function with only one RPM. If you insert a second RPM, it comes online as the standby RPM. To display the
status of installed RPMs, enter the show rpm all command.
Dell# show rpm all
-- Route Processor Modules --
Slot Status NxtBoot Version
------------------------------------------
0 active online 1-0(0-4095)
1 standby online 1-0(0-4095)
Line Card Online Insertion
When you insert a line card into an online chassis, the Dell Networking OS detects the line card type. The system writes the line card type
to the running conguration and maintains this information as a logical conguration if you remove the card. To display the status of
installed line cards, enter the show linecard all command.
Dell# show linecard all
-- Linecard Info --
LinecardId Type Status ReqTyp CurTyp Version Ports
----------------------------------------------------------------------------
0 Linecard online C9000LC2410T C9000LC2410T 1-0(0-4095) 24
1 Linecard online C9000LC2410G C9000LC2410G 1-0(0-4095) 24
2 Linecard online C9000LC2410T C9000LC2410T 1-0(0-4095) 24
3 Linecard online C9000LC2410T C9000LC2410T 1-0(0-4095) 24
4 Linecard online C9000LC0640 C9000LC0640 1-0(0-4095) 24
5 Linecard online C9000LC0640 C9000LC0640 1-0(0-4095) 24
6 Linecard online C9000LC0640 C9000LC0640 1-0(0-4095) 24
7 Linecard online C9000LC0640 C9000LC0640 1-0(0-4095) 24
8 Linecard online C9000LC2410G C9000LC2410G 1-0(0-4095) 24
9 Linecard online C9000LC2410G C9000LC2410G 1-0(0-4095) 24
10 Linecard online C9000-RPM-2.56T C9000-RPM-2.56T 1-0(0-4095) 4
11 Linecard online C9000-RPM-2.56T C9000-RPM-2.56T 1-0(0-4095) 4
Pre-conguring a Slot for a Line-Card Type
You can pre-congure an empty line-card slot with a logical line card by using the linecard slot-id provision card-type
command. After you create the logical line card, you can congure interfaces on the line card as if it is present in the chassis. If the card
fails, the system maintains the logical conguration for the slot.
The C9010 supports the following line cards and card types:
6-Port 40 Gigabit Ethernet QSFP+ (card type: C9000LC0640)
24-Port 1/10 Gigabit Ethernet SFP+ (card type: C9000LC2410G)
24-Port 1/10 Gigabit Ethernet Base-T RJ-45 (card type: C9000LC2410T)
Dell(conf)# linecard 3 provision C9000LC2410G
Dell(conf)# end
High Availability (HA)
409