Administrator Guide

A warning is displayed with a CLI prompt asking you to click Yes or No
Dell#diag system
Warning - diagnostic execution will cause multiple link flaps on the peer side -
advisable to shut directly connected ports
Proceed with Diags [confirm yes/no]:
5. View the results of the diagnostic tests.
EXEC Privilege Mode
show file flash://TestReport-CP-unit.txt
show file flash://TestReport-LP-linecard-number.txt
The following example takes a switch offline.
Dell#offline system
Warning - offline of system will bring down all the protocols and
the system will be operationally down, except for running Diagnostics.
The "reload" command is required for normal operation after the offline command is issued.
Proceed with Offline [confirm yes/no]:yes
% Error: linecard 0 is not present.
% Error: linecard 2 is not present.
% Error: linecard 3 is not present.
% Error: linecard 6 is not present.
% Error: linecard 7 is not present.
% Error: linecard 8 is not present.
% Error: linecard 9 is not present.
Apr 26 22:26:17: %RPM0-P:CP %CHMGR-2-LINECARD_DOWN: linecard 4 down - linecard offline
% Error: linecard 11 is not present.
Dell#Apr 26 22:26:17: %RPM0-P:CP %IFMGR-1-DEL_PORT: Removed port: Fo 4/0-20,
Apr 26 22:26:17: %RPM0-P:CP %CHMGR-2-LINECARD_DOWN: linecard 5 down - linecard offline
Apr 26 22:26:17: %RPM0-P:CP %IFMGR-1-DEL_PORT: Removed port: Te 5/0-7, Fo 5/8-20,
Apr 26 22:26:17: %RPM0-P:CP %CHMGR-2-LINECARD_DOWN: linecard 10 down - linecard offline
Apr 26 22:26:17: %RPM0-P:CP %IFMGR-1-DEL_PORT: Removed port: Te 10/0-3,
Apr 26 22:26:17: %RPM0-P:CP %CHMGR-2-LINECARD_DOWN: CP unit down - CP unit offline
The following example verifies the offline/online status of a switch.
Dell#show chassis brief
Chassis Type : C9010
Chassis Mode : 1.0
Chassis MAC : 34:17:eb:01:d4:00
-- Linecard Info --
LinecardId Type Status ReqTyp CurTyp Version Ports
----------------------------------------------------------------
0 Linecard not present
1 Linecard card problem unknown -
2 Linecard not present
3 Linecard not present
4 Linecard offline C9000LC0640 C9000LC0640 1-0(0-4854) 24
5 Linecard offline C9000LC0640 C9000LC0640 1-0(0-4854) 24
6 Linecard not present
7 Linecard not present
8 Linecard not present
9 Linecard not present
10 Linecard card problem C9000-RPM-2.56T C9000-RPM-2.56T 1-0(0-4854) -
11 Linecard not present
-- Route Processor Modules --
Slot Status NxtBoot Version
----------------------------------------------------------------
0 active online 1-0(0-4854)
1 not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm) Power Usage (W)
---------------------------------------------------------------
278
Debugging and Diagnostics