Administrator Guide

PORT-EXTENDER CONFIGURATION mode
Dell(conf-pe-0)# cascade interface interface-type slot/port-range
interface interface-type specifies a C9010 10-Gigabit Ethernet interface. The only supported value is
TenGigabitEthernet slot/port-range.
slot/port-range specifies a C9010 10GbE port, including slot number and either a single port number, a port range, or a
combination of both for auto-LAG configuration.
The range of slot numbers is from 0 to 11. In line-card slots 0 to 9, the range of port numbers is from 0 to 23; in RPM slots 10
and 11, the range of port numbers is from 0 to 3.
Enter a port range with or without spaces; for example, cascade interface tengigabitethernet 0/1-5 or
cascade interface tengigabitethernet 0/1 - 5.
You can enter up to six comma-separated ranges or port numbers; for example, cascade interface
tengigabitethernet 0/1-2,8,10–12,15.
5. Verify the provisioned configuration on a C1048P.
EXEC Privilege mode
Dell# show pe brief
Dell# show pe pe-id
Dell# show interface port-channel brief
Dell(conf)# feature extended-bridge
Dell(conf)# pe provision 2
Dell(conf-pe-2)# stack-unit 0 type c1048p
Dell(conf-pe-2)# cascade interface tengigabitethernet 0/1–2
Dell(conf-pe-2)# exit
Dell(conf)# interface range tengigabitethernet 0/1-2
Dell(conf-if-te-0/1–2)# no shutdown
Dell(conf-if)# end
Dell#show pe 255 brief
-- Port Extenders Information --
---------------------------------------------------------------------------------------
PE-id Status Stack-size Type System-MAC Description
---------------------------------------------------------------------------------------
255 online 2 N3048-PE f8:b1:56:33:ee:f2
NOTE:
If the status of a port extender is error, communication with an attached C9010 was unsuccessful, possibly due
to a mismatch in software version (SVM) or another communication error. Wait five minutes for an auto-upgrade of the
port extender to complete. If the status does not change to online, contact Dell Networking Support for assistance.
Dell#show pe 1
Codes: A - Active, I - Inactive
SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 1
Status: online
System Mac: f8:b1:56:73:a2:91
PE Up Time: 03:00:27
PE Description:
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/16(A)
Cascade LAG: Po 259, Local Status: Up, Remote Status: Down
PE Configuration: Local Status: Present, Remote Status: Not Present
---------------------------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports Description
---------------------------------------------------------------------------------------------
0 online - N2048P-PE f8:b1:56:73:a2:91 52
1 online - N2048P-PE f8:b1:56:73:a2:89 52
2 online - N3024P-PE f4:8e:38:02:b1:43 30
666
Port Extenders (PEs)