Administrator Guide

changed to 1 (Current temperature 36C).
Apr 3 00:41:02: %PE200-UNIT2-M:CP %SEC-5-LOGIN_SUCCESS: Login successful on console
Apr 3 00:41:03: %PE200-UNIT2-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up:
Po 257
Apr 3 00:41:03: %PE200-C1048P:2 %IFAGT-5-INSERT_OPTICS_PLUS: Optics SFP+ inserted in slot
2 port 1
Apr 3 00:41:03: %PE200-C1048P:2 %IFAGT-5-UNSUP_OPTICS: Non-qualified optics in slot 2 port
2
Apr 3 00:41:03: %PE200-UNIT2-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 2/1
Apr 3 00:41:03: %PE200-UNIT2-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Te 2/2
Apr 3 00:41:23: %PE200-UNIT2-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Po 257
Apr 3 05:55:02: %PE200-UNIT2-M:CP %EVL-6-EVENT_LOGGING: Start uploading pre-recorded
traps(count:15) to CB
Apr 3 05:55:04: %PE200-UNIT2-M:CP %EVL-6-EVENT_LOGGING: Completed uploading pre-recorded
traps(send count:15, pending traps:0) to CB
Dell#
Dell#show pe brief
-- Port Extenders Information --
----------------------------------------------------------
PE-id Status Stack-size Type System-MAC
----------------------------------------------------------
200 online 1 C1048P f8:b1:56:00:02:8a
Dell#show pe 200
Codes: A - Active, I - Inactive
SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 200
Status: online
System Mac: f8:b1:56:00:02:8a
PE Up Time: 00:01:25
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/22(A),Te 0/23(A)
Cascade LAG: Po 458(Up)
------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
------------------------------------------------------------------------
2 online - C1048P f8:b1:56:00:02:8a 52
Dell#
The PE comes online after the auto-synch. To get a dual homing setup, refer to Setting up Dual Homing.
Upgrading from OS 9.10(0.0)
To upgrade a dual homing setup with Dell Networking OS 9.10(0.0) to later versions, perform the following steps:
In the following example, C9010–1 is the primary system and C9010–2 is secondary. The VLT peers and the PEs in the setup are
upgraded from Dell Networking OS 9.10(0.1) to 9.11(0.0). After the upgrade is completed, the VLT peers exchange the roles. C9010–2
becomes the secondary VLT peer and C9010–1 takes up the secondary role.
1. Upgrade boot partition in secondary VLT peer with new software image.
C9010-2#upgrade system-image all tftp://10.11.8.184/users/dellnetworking/FTOS-
C9000-9.11.0.0.bin B:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
146025615 bytes successfully copied
Image upgraded to CP.
!!!!!!!!!!!!!!!!!!!!!!!!
Image upgraded to RP and Standby RPM.
C9010-2#
C9010-2#upgrade system-image linecard all rpmB:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Port Extenders (PEs)
687