Administrator Guide

SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 2
Status: online
System Mac: a0:68:00:3f:92:bc
PE Up Time: 14:06:37
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/0(A)
Cascade LAG: Po 258, Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
---------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
On the secondary VLT peer:
Dell# show pe 2
Codes: A - Active, I - Inactive
SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 2
Status: online
System Mac: a0:68:00:3f:92:bc
PE Up Time: 14:06:37
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/4(A)
Cascade LAG: Po 258, Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
---------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
Adding a Unit to an Existing PE Stack
You can add a stack unit to an existing stack as follows:
1. Disconnect a stack cable from the stack’s ring topology. Re-attach the cable to a stacking port on the back panel of the new unit.
2. Attach a cable from the second stack port on the new unit to the stack port on a unit in the ring.
3. Power on the new unit.
After the new unit loads and the parent C9010 discovers it, the preconfigured software settings download from the C9010. The new unit
functions as part of the stack.
Renumbering a Stack Unit
By default, the number of a PE stack unit is 0. After you create and power on a PE stack, the units automatically number from 0 to 7,
starting at 0. To change the default or automatically assigned stack unit number, use the pe renumber command.
NOTE: You can renumber a unit only when it is online and if no unit with the new stack-unit number is online.
Configure a stack-unit number.
EXEC Privilege mode
pe pe-id stack-unit unit-id renumber unit-id
694
Port Extender (PE) Stacking