Users Guide

QSFP 168 Connector = 0x07
QSFP 168 Transceiver Code = 0x02 0x00 0x00 0x00 0x00 0x00 0x00 0x00
QSFP 168 Encoding = 0x05
QSFP 168 Length(SFM) Km = 0x0a
QSFP 168 Length(OM3) 2m = 0x00
QSFP 168 Length(OM2) 1m = 0x00
QSFP 168 Length(OM1) 1m = 0x00
QSFP 168 Length(Copper) 1m = 0x00
QSFP 168 Vendor Rev = X
QSFP 168 Laser Wavelength = 1301.00 nm
QSFP 168 CheckCodeBase = 0x19
QSFP 168 Serial ID Extended Fields
QSFP 168 BR max = 0
QSFP 168 BR min = 0
QSFP 168 Vendor SN = Z12I00005
QSFP 168 Datecode = 130117
QSFP 168 CheckCodeExt = 0xe8
QSFP 168 Diagnostic Information
===================================
QSFP 168 Rx Power measurement type = Average
===================================
QSFP 168 Temp High Alarm threshold = 80.000C
QSFP 168 Voltage High Alarm threshold = 3.630V
QSFP 168 Bias High Alarm threshold = 120.000mA
QSFP 168 RX Power High Alarm threshold = 2.138mW
QSFP 168 Temp Low Alarm threshold = -10.000C
QSFP 168 Voltage Low Alarm threshold = 2.970V
QSFP 168 Bias Low Alarm threshold = 5.000mA
QSFP 168 RX Power Low Alarm threshold = 0.017mW
===================================
QSFP 168 Temp High Warning threshold = 75.000C
QSFP 168 Voltage High Warning threshold = 3.465V
QSFP 168 Bias High Warning threshold = 100.000mA
QSFP 168 RX Power High Warning threshold = 1.698mW
QSFP 168 Temp Low Warning threshold = -5.000C
QSFP 168 Voltage Low Warning threshold = 3.135V
QSFP 168 Bias Low Warning threshold = 10.000mA
QSFP 168 RX Power Low Warning threshold = 0.043mW
===================================
QSFP 168 Temperature = 21.891C
QSFP 168 Voltage = 3.314V
QSFP 168 TX1 Bias Current = 0.000mA
QSFP 168 TX2 Bias Current = 0.000mA
QSFP 168 TX3 Bias Current = 0.000mA
QSFP 168 TX4 Bias Current = 0.000mA
QSFP 168 RX1 Power = 0.000mW
QSFP 168 RX2 Power = 0.000mW
QSFP 168 RX3 Power = 0.000mW
QSFP 168 RX4 Power = 0.000mW
Recognize an Over-Temperature Condition
An alarm message is generated and displayed when an over-temperature condition on a system component occurs. Either a
minor or a major alarm is triggered.
When the minor temperature alarm condition is met on the linecard or RPM, the fan speed is increased from 70% to 80%.
When the major temperature alarm condition is met on the linecard or RPM, the fan speed is increased from 90% to 100%.
Over-temperature alarms are logged. Use the show alarms command to display the currently logged alarms.
To display the pre-configured sensor thresholds, use the show alarms threshold command.
Dell#show alarm threshold
-- Temperature Limits (deg C) --
Debugging and Diagnostics 318