Users Guide

feature extended-bridge
!
pe provision 10
cascade interface TenGigabitEthernet 1/0
stack-unit 0 type C1048P
stack-unit 0 priority 1
!
pe provision 20
cascade interface TenGigabitEthernet 1/12
Dell# show pe brief
- Port Extenders Information --
----------------------------------------------------------
PE-id Status Stack-size Type System-MAC
----------------------------------------------------------
10 online 1 C1048P a0:68:00:3f:92:bc
20 offline 1 C1048P 00:00:00:00:00:00
Dell#show pe errors
PE-id: 10
PE MAC: a0:68:00:3f:92:bc
Interface Errors:
TenGigabitEthernet 1/12 - Error State
You may connect two PEs to a parent C9010 but only provision one PE with cascade ports. In this case, only the PE
connected to the lowest numbered cascade port comes online. In the following example, PE 10 is provisioned with cascade
ports 1/0, 8, and 12. However, only cascade ports 1/0 and 1/12 are cabled to PE 10; port 1/8 is cabled to a different PE. As a
result, only PE 10 comes online becomes it is connected to the lowest numbered cascade port: port 1/0. Port 1/8 is placed
in an error state and the PE to which it connects does not come online.
Dell# show running-config pe
!
feature extended-bridge
!
pe provision 10
cascade interface TenGigabitEthernet 1/0,8,12
stack-unit 0 type C1048P
Dell# show pe
Maximum number of PE Units allowed: 40
Current number of PE units in the system: 1
Codes: A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 10
Status: online
System Mac: 00:01:02:03:11:01
PE Up Time: 00:02:14
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/0(A),Te 1/8(I),Te 1/12(A)
Cascade LAG: Po 268(Up)
---------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------------
0 online - C1048P 00:01:02:03:11:01 52
Dell#show pe errors
PE-id: Not Assigned
PE MAC: 00:01:02:03:22:02
Interface Errors:
TenGigabitEthernet 1/8 - Error State
You may connect a PE to a parent C9010 using both uplink ports but provision the PE with only the cascade port attached
to one of the uplink ports. In this case, the auto-LAG is created with only the provisioned cascade port when the PE comes
Port Extenders (PEs) 689