Users Guide

Linecard3 Boot Flash 3.3.1.16 3.3.1.18
Linecard4 Boot Flash 3.3.1.16 3.3.1.18
Linecard5 Boot Flash 3.3.1.16 3.3.1.18
Linecard6 Boot Flash 3.3.1.16 3.3.1.18
Linecard7 Boot Flash 3.3.1.16 3.3.1.18
Linecard8 Boot Flash 3.3.1.16 3.3.1.18
Linecard9 Boot Flash 3.3.1.16 3.3.1.18
Linecard10 Boot Flash 3.3.1.16 3.3.1.18
Linecard11 Boot Flash 3.3.1.16 3.3.1.18
PE (0/0) Boot Flash 3.3.1.7 3.3.1.7
PE (0/1) Boot Flash 3.3.1.7 3.3.1.7
***********************************************************************
* Warning - Upgrading boot flash is inherently risky and should only *
* be attempted when necessary. A failure at this upgrade may cause *
* a board RMA. Proceed with caution ! *
***********************************************************************
Proceed Boot Flash image for all cards [yes/no]: yes
!!!!!!Sep 7 19:20:23: %RPM0-P:CP %DOWNLOAD-6-UPGRADE: PE 0 manual upgrade result - upgrade
success.
!!!!!
Bootflash image upgrade for all cards completed successfully.
Warning: Kindly save the system configuration before reloading.
Dell#
2 Use the upgrade system-image all command to upgrade the image in both the CB and the PE.
Dell#upgrade system-image all ftp: B:
Address or name of remote host []: 10.16.127.141
Source file name []: $w/Releases/E9.9.0/E9.9.0.0/FTOS-C9000-9.9.0.0.bin
User name to login remote host: admin
Password to login remote
host: !!!!!!!!!!!!!!!Sep 6
19:16:06: %RPM0-P:CP %KERN-6-INT: CP Mgmt port receiving excessive traffic; will be rate
controlled
- repeated 6 times
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Sep 6 19:16:58: %RPM0-P:CP %KERN-6-INT:
CP Mgmt port receiving excessive traffic; will be rate controlled
- repeated 12 times
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Sep 6 19:17:27: %RPM0-P:CP %KERN-6-INT: CP CPU receiving
excessive Management traffic: rx is suspended
!....!!!!Sep 6 19:17:36: %RPM0-P:CP %KERN-6-INT: CP Mgmt port receiving excessive traffic;
will be rate controlled
!!.........................!.................................................................
...
Image upgraded to CP.
!!!!!!!!!!!!!!%PE200-UNIT2-M:CP %DOWNLOAD-6-UPGRADE: Upgrade request received from
Controlling Bridge.
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!Apr 3 08:47:20: %RPM1-P:CP %DOWNLOAD-6-UPGRADE: PE 200 manual upgrade result -
upgrade success.
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
PE (200) Image upgraded successfully.
Image upgraded to RP, Standby RPM and all linecards.
3 Use the reload pe option to reload both CB and PE.
The above procedure brings up the devices in Dell Networking OS 9.10(0.0). To get a dual homing setup, you need to have
a VLT domain running in two systems with the same OS version. Refer to Setting up Dual Homing.
When you upgrade a standalone system to OS 10.0(0.0) and then connect a PE later, there might be a mismatch between
the versions. In this situation, the PE remains offline and the system displays the following:
Dell#
Apr 3 05:47:19: %RPM1-P:CP %DOWNLOAD-6-VERSION_MISMATCH_INFO: Received checkin from PE 200.
Expected version = 9-10(0-60) checkin version = 9.9(0.0)
Port Extenders (PEs) 702