Users Guide

0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
Example of Dual Homed PE Stack
Dell(conf-b)#pe provision 2
Dell(conf-b-pe-2)#cascade interface TenGigabitEthernet 0/0
Dell(conf-b-pe-2)#cascade interface TenGigabitEthernet 1/4 peer
Dell(conf-b)#commit
Dell(conf-b)#end
Dell# show pe 2
Codes: A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - CHM Validation Error
PE-ID assigned: 2
Status: online
System Mac: a0:68:00:3f:92:bc
PE Up Time: 14:06:37
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/0(A)
Cascade LAG: Po 258, Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
---------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
On the secondary VLT peer:
Dell# show pe 2
Codes: A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - CHM Validation Error
PE-ID assigned: 2
Status: online
System Mac: a0:68:00:3f:92:bc
PE Up Time: 14:06:37
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/4(A)
Cascade LAG: Po 258, Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
---------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
---------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
Adding a Unit to an Existing PE Stack
You can add a stack unit to an existing stack as follows:
1. Disconnect a stack cable from the stack’s ring topology. Re-attach the cable to a stacking port on the back panel of the
new unit.
2. Attach a cable from the second stack port on the new unit to the stack port on a unit in the ring.
3. Power on the new unit.
Port Extender (PE) Stacking 709