For a port extender Gigabit Ethernet interface, enter the keyword peGigE then the
pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255; the stack-
unit unit-number range is from 0 to 7; and the port-id range is from 1 to 48.
For a port extender 10-Gigabit Ethernet interface, enter the keyword peTenGigE
then the pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255;
the stack-unit unit-number range is from 0 to 7; and the port-id range is 25 to 28 or
49 to 52 depending on the PE.
NOTE: The peGigE or peTenGigE option is only visible when the feature
extended bridge feature is enabled.
linecard
slot-id
Enter the linecard slot-id parameters to specify the switch ports on a line card.
The range of slot IDs is from 0 to 11.
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.13.0.1P1 Introduced peTenGigE interface support on the C9010.
9.9(0.0) Introduced on the C9010 and C1048P.
9.2(1.0) Introduced on the Z9500.
9.2(0.0) Added support for the tunnel interface type.
9.1(0.0) Updated ManagementEthernet output to include two global IPv6 addresses on S4810 and
Z9000 and added output example showing OpenFlow instance ID.
8.3.12.1 Updated command output to support multiple IPv6 addresses on S4810.
8.3.11.4 Output expanded to support eSR4 optics in Z9000.
8.3.11.1 Introduced on the Z9000.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.3.7.0 Introduced on the S4810.
8.2.1.2 Included SFP and SFP+ optics power detail in the E-Series and C-Series output.
8.2.1.0 Added support for 4093 VLANs on the E-Series ExaScale. Prior releases supported 2094.
8.1.1.0 Introduced on the E-Series ExaScale.
7.8.1.0 Output expanded to include SFP+ media on the C-Series.
7.6.1.0 Introduced on the S Series.
7.5.1.0 Introduced on the C-Series.
6.4.1.0 Changed the organization of the display output.
6.3.1.0 Added the Pluggable Media Type field in the E-Series TeraScale output.
Usage Information
Use the show interfaces command for details on a specific interface. Use the show interfaces
linecard command for details on all interfaces on the designated line card.
NOTE: In the CLI output, the power value is rounded to a 3-digit value. For receive/transmit power
that is less than 0.000, an snmp query returns the corresponding dbm value even though the CLI
displays as 0.000.
NOTE: After the counters are cleared, the line-rate continues to increase until it reaches the
maximum line rate. When the maximum line rate is reached, there is no change in the line-rate.
712 Interfaces