Administrator Guide

Parameters
interface
Enter the keyword TenGigabitEthernet , peGigE or peTenGigE then the slot/
port information for the 100/1000 Ethernet interface.
Defaults None
Command Modes EXEC
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.13.0.1P1 Introduced peTenGigE interface support on the C9010.
9.10(0.1) Introduced on the S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.9(0.0) Introduced on the C9010.
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7.0.0 Introduced on the S5000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
6.1.1.0 Introduced.
Usage Information If the TDR test has not been run, an error message is generated:
%Error: Please run the TDR test first
The following describes the TDR test status.
Status Definition
OK Status:
Terminated
TDR test is complete, no fault is detected on the cable, and the test is terminated.
Length: 92 (+/- 1)
meters, Status:
Shorted
A short is detected on the cable. The location, in this Example is 92 meters. The short is
accurate to plus or minus one meter.
Length: 93 (+/- 1)
meters, Status:
Open
An opening is detected on the cable. The location, in this Example is 93 meters. The open
is accurate to plus or minus one meter.
Status: Impedance
Mismatch
There is an impedance mismatch in the cables.
Example
DellEMC# show tdr tengigabitethernet 11/2
Time since last test: 00:00:11
Pair A, Length: OK Status: Terminated
Pair B, Length: OK Status: Terminated
Pair C, Length: OK Status: Terminated
Pair D, Length: OK Status: Terminated
Related
Commands
tdr-cable-test — run the TDR test.
Interfaces 775