Users Guide

---------------------------------------------------------------
0 0 up up 7943 up 7992 up 7975 up 8008
0 1 up up 7975 up 8008 up 7992 up 7975
0 2 up up 7959 up 7959 up 7959 up 7975
Speed in RPM
The following example runs offline diagnostics on a standalone switch
Dell#diag system
Warning - diagnostic execution will cause multiple link flaps on the peer side -
advisable to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
% Error: Invalid command - card is not present.
% Error: Invalid command - card must be offline.
% Error: Invalid command - card is not present.
% Error: Invalid command - card is not present.
% Error: Invalid command - card is not present.
% Error: Invalid command - card is not present.
% Error: Invalid command - card is not present.
% Error: Invalid command - card is not present.
% Error: Invalid command - card is not present.
Dell#Apr 26 22:32:01: %C9000LC0640:4 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on
linecard 4
2d3h3m : Approximate time to complete the Diags (all levels)... 10 Mins
Apr 26 22:32:01: %C9000LC0640:5 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on
linecard 5
2d3h3m : Approximate time to complete the Diags (all levels)... 10 Mins
Apr 26 22:32:01: %C9000-RPM-2.56T:10 %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on
linecard 10
2d3h3m : Approximate time to complete the Diags (all levels)... 10 Mins
Apr 26 22:32:01: %SYSTEM:LP %DIAGAGT-6-DA_DIAG_STARTED: Starting diags on CP unit
2d3h3m : Approximate time to complete the Diags (all levels)... 10 Mins
Apr 26 22:33:07: %RPM0-P:CP %IPC-2-STATUS: target line card 10 not responding
Apr 26 22:33:07: %RPM0-P:CP %CHMGR-2-LINECARD_DOWN: Major alarm: linecard 10 down
- IPC timeout
2d3h4m : Diagnostic test results are stored on file: flash:/TestReport-LP-5.txt
2d3h4m : Diagnostic test results are stored on file: flash:/TestReport-LP-4.txt
Apr 26 22:33:13: %C9000LC0640:5 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on
linecard 5
2d3h4m : Recommended to reboot the system after diagnostics!!!
Apr 26 22:33:14: %C9000LC0640:4 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on
linecard 4
2d3h4m : Recommended to reboot the system after diagnostics!!!
2d3h7m : Diagnostic test results are stored on file: flash:/TestReport-CP-unit.txt
Apr 26 22:36:01: %SYSTEM:LP %DIAGAGT-6-DA_DIAG_DONE: Diags finished on CP unit
2d3h7m : Recommended to reboot the system after diagnostics!!!
Dell#dir flash:
Directory of flash:
1 drwx 4096 Jan 01 1980 00:00:00 +00:00 .
2 drwx 2280 Apr 26 2015 22:42:17 +00:00 ..
3 d--- 4096 Aug 14 2014 02:26:48 +00:00 ADMIN_DIR
4 drwx 12288 Aug 14 2014 02:26:48 +00:00 CORE_DUMP_DIR
5 drwx 4096 Sep 12 2014 16:13:24 +00:00 TRACE_LOG_DIR
6 drwx 4096 Aug 14 2014 03:00:40 +00:00 DCLI_LOG_DIR
7 drwx 4096 Sep 12 2014 16:13:24 +00:00 CONFD_LOG_DIR
8 -r-x 0 Nov 30 2014 04:07:40 +00:00 localcfg
9 drwx 8192 Sep 12 2014 16:13:24 +00:00 CRASH_LOG_DIR
10 drwx 4096 Sep 12 2014 16:13:24 +00:00 RUNTIME_PATCH_DIR
11 drwx 4096 Dec 24 2014 14:11:02 +00:00 gdb
12 drwx 4096 Sep 25 2014 10:43:12 +00:00 grubdir
Debugging and Diagnostics 350