Users Guide

Beginning Metric Style Final Metric Style Resulting IS-IS Metric Value
narrow wide original value
narrow transition original value
narrow narrow transition original value
narrow wide transition original value
transition wide original value
transition narrow original value
transition narrow original value
transition wide transition original value
narrow transition wide original value
narrow transition narrow original value
narrow transition wide transition original value
narrow transition transition original value
wide transition wide original value
wide transition narrow default value (10) if the original
value is greater than 63. A message
is sent to the console.
wide transition narrow transition default value (10) if the original
value is greater than 63. A message
is sent to the console.
wide transition transition truncated value (the truncated
value appears in the LSP only). The
original isis metric value is
displayed in the show config and
show running-config
commands and is used if you
change back to transition metric
style.
Moving to transition and then to another metric style produces different results.
Table 42. Metric Value when the Metric Style Changes Multiple Times
Beginning Metric
Style
Next Metric Style Resulting Metric
Value
Next Metric Style Final Metric Value
wide transition truncated value wide original value is
recovered
wide transition transition truncated value wide transition original value is
recovered
Intermediate System to Intermediate System 605