Users Guide

0 error SVM C1048P 00:00:00:00:00:00 52
Dell#show pe 10 statistics
PE-ID: 10
PE-CSP Tx Message: 4
PE-CSP Rx Message: 2
ECP Tx: 5
ECP Rx Ack: 5
ECP Dropped: 0
ECP Rx: 3
ECP Tx Ack: 3
ell#show pe 10 system brief
Stack MAC : a0:68:00:3f:92:bc
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-----------------------------------------------------------------------------------
-
0 Management online C1048P C1048P 9-9(0-5) 52
1 Member not present
2 Standby not present C1048P
3 Member not present C1048P
4 Member not present
5 Member not present
6 Member not present
7 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-------------------------------------------------------------------------
0 0 up AC NA NA
0 1 absent NA NA
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
-----------------------------------------------------------------------------------
-
0 0 up up 8888 up 9056
Speed in RPM
For more information about verifying the PE configuration, see Displaying PE Stack Information.
Resetting a Port Extender
To reload a PE, enter the reset command.
reset pe pe-id stack-unit pe-stack-unit-id
EXEC Privilege
pe-id is a port-extender ID number from 0 to 255.
pe-stack-unit-id is a PE stack-unit ID number from 0 to 7.
Dell# reset pe 0 stack-unit 1
Port Extenders (PEs) 827