Users Guide

0 Management online C1048P C1048P 1-0(0-4149) 52
1 Member not present
2 Member not present
3 Standby online C1048P C1048P 1-0(0-4149) 52
4 Member not present
5 Member not present
6 Member not present
7 Member not present
Verifying a PE Stack Master and Standby
The Status LED on the front panel of a PE stack unit identifies the unit’s role in the stack.
Off indicates that the unit is a stack member.
Off also indicates that the unit is stack standby.
Solid green indicates that the unit is the stack master (management unit).
Displaying PE Stack Information
To display information about a PE stack configuration, enter the following show commands in EXEC Privilege
mode.
Display information about PE stack units connected to the C9010, including the discovery status.
show pe
Dell# show pe
Maximum number of PE Units allowed: 40
Current number of PE units in the system: 8
Codes: A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 0
Status: online
System Mac: a0:68:00:3f:92:bc
PE Up Time: 14:13:03
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/0(A),Te 2/22(A)
Cascade LAG: Po 258(Up)
-------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
-------------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
3 online - C1048P 62:74:00:41:54:c8 52
4 online - C1048P 62:74:00:41:54:c9 52
5 online - C1048P cb:28:00:42:bd:7c 52
6 online - C1048P 62:74:00:41:54:01 52
7 online - C1048P 6c:c0:00:43:11:11 52
Display summary information about the PE stack units attached to the master PE. Enter the PE ID of the
master unit.
Port Extender (PE) Stacking 853