Administrator Guide

0 (type C9000LC0640, 24 ports)
Jun 24 15:28:24: %RPM1-P:CP %CHMGR-5-LINECARD_UP: linecard 0 is up
Jun 24 15:28:28: %C9000LC0640:0 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP
inserted in slot 0 port 0
Jun 24 15:28:28: %C9000LC0640:0 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP
inserted in slot 0 port 4
Jun 24 15:28:28: %C9000LC0640:0 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP
inserted in slot 0 port
16
Example: pe
stack-unit
Dell#reset stack-unit 2
Dell#Jun 24 15:19:52: %PE255-UNIT1-M:CP %CHMGR-5-STACKUNIT_RESET: stack-
unit 2 being reset
Jun 24 15:19:52: %PE255-UNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 2
down - reset
Jun 24 15:19:53: %PE255-UNIT1-M:CP %IFMGR-5-OSTATE_DN: Changed interface
state to down: Te 2/48
Jun 24 15:19:53: %PE255-UNIT1-M:CP %IFMGR-1-DEL_PORT: Removed port: Te
2/48-49,
Jun 24 15:19:53: %PE255-UNIT2-S:CP %IFMGR-1-DEL_PORT: Removed port: Te
2/48-49,
Jun 24 15:19:58: %PE255-UNIT1-M:CP %POLLMGR-2-ALT_STACKUNIT_STATE:
Alternate Stack-unit is not present
Jun 24 15:19:58: %PE255-UNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 2
down - card removed
Jun 24 15:20:06: %PE255-UNIT1-M:CP %POLLMGR-2-ALT_STACKUNIT_STATE:
Alternate Stack-unit is not present
Jun 24 15:20:06: %PE255-UNIT1-M:CP %POLLMGR-2-ALT_STACKUNIT_STATE:
Alternate Stack-unit is present
Jun 24 15:21:06: %PE-UNKN-UNIT3-S:CP %RAM-5-STACKUNIT_STATE: Stack-unit
3 is in Standby State.
Jun 24 15:21:08: %PE255-UNIT3-S:CP %EVL-6-EVENT_LOGGING: Start uploading
pre-recorded traps(count:1) to CB
Jun 24 15:21:09: %PE255-UNIT3-S:CP %EVL-6-EVENT_LOGGING: Completed
uploading pre-recorded traps(send count:1, pending traps:0) to CB
Jun 24 15:21:21: %PE255-UNIT1-M:CP %CHMGR-5-STACKUNIT_DETECTED: stack-
unit 2 present
Jun 24 15:21:23: %PE255-UNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from stack-
unit 2 (type C1048P, 52 ports)
Jun 24 15:21:23: %PE255-UNIT1-M:CP %CHMGR-5-STACKUNIT_UP: stack-unit 2
is up
Jun 24 15:21:25: %PE-UNKN-C1048P:2 %IFAGT-5-INSERT_OPTICS_PLUS: Optics
SFP+ inserted in slot 2 port 48
Jun 24 15:21:26: %PE-UNKN-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Jun 24 15:21:26: %PE255-UNIT1-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 0
of Unit 2 is inserted
Jun 24 15:21:26: %PE255-UNIT1-M:CP %CHMGR-0-PS_UP: Power supply 0 in
unit 2 is up
Jun 24 15:21:26: %PE255-UNIT1-M:CP %CHMGR-0-PS_UP: Power supply 1 in
unit 2 is up
Jun 24 15:21:26: %PE-UNKN-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Jun 24 15:21:26: %PE255-UNIT1-M:CP %IFMGR-5-OSTATE_UP: Changed interface
state to up: Te 2/48
Jun 24 15:21:27: %PE-UNKN-C1048P:2 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 75 % of the full speed
Jun 24 15:21:27: %PE255-UNIT1-M:CP %CHMGR-4-TEMP_STATUS_CHANGE: Unit 2
temperature state changed to 1 (Current temperature 35C).
Related
Commands
reload reboots the Dell Networking OS.
PE Stacking 1271