Administrator Guide

Field Description
CP Boot Flash Displays the two possible Boot Flash versions for the control processor. The
[Booted] keyword next to the version states which version was used at system
boot.
RP Boot Flash Displays the Boot Flash version for the Routing Processor. The [Booted] keyword
next to the version states which version was used at system boot.
CP Mem Size Displays the memory of the control processor.
RP Mem Size Displays the memory of the Routing Processor.
Temperature Displays the temperature of the RPM. Minor alarm status if the temperature is over
65°C.
Power Status Lists the status of the power modules in the chassis.
Voltage Displays the power rails for the line card.
Part Num Displays the line card part number.
Vendor ID Displays an internal code, which specifies the manufacturing vendor.
Date Code Displays the line cards manufacturing date.
Country Code Displays the country of origin. 01 = USA.
Example
Dell#show rpm 0
-- RPM card 0 --
Status : active
Next Boot : online
Card Type : RPM - Route Processor Module (C9000-RPM-2.56T)
Hardware Rev : 4.0
Num Ports : 1
Up Time : 21 min, 28 sec
Last Restart : normal power-cycle
Dell Networking OS Version : 9.9(0.0)
Jumbo Capable : yes
CP Boot Flash : 3.3.1.16 [booted]
RP Boot Flash : 3.3.1.16 [booted]
Boot Selector : 3.3.0.1
RP Boot Selector : 3.3.0.1
CP Mem Size : 2127536128 bytes
RP Mem Size : 2127536128 bytes
Temperature : 28C 54C
Power Status : AC
Voltage : ok
Serial Number : NA
Part Number : 0CKKCP Rev X00
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : CN-0CKKCP-77931-466-0009
PPID Revision : X00
Service Tag : 13NRG02
Expr Svc Code : 239 809 248 2
Auto reboot : Disabled
Dell#show rpm 0 brief
-- RPM card 0 --
Status : active
Next Boot : online
Card Type : RPM - Route Processor Module (C9000-RPM-2.56T)
Hardware Rev : 4.0
Num Ports : 1
Up Time : 32 min, 25 sec
Last Restart : normal power-cycle
Control and Monitoring
135