Administrator Guide

3 C1048P-01-1G-48 NA 7590009701 001 US-0F14T0-77951-3AG-000A 01
NA NA
1 C1048P-PWR-AC N/A N/A
N/A N/A
1 C1048P-FAN N/A N/A
N/A N/A
3 C1048P-PWR-AC N/A N/A N/
A N/A
3 C1048P-FAN N/A N/A N/
A N/A
* 1 usbflash: 40962316 - 11.00 N/A N/A N/
A N/A
* - Management Unit
Software Protocol Configured
------------------------------------------------------------
LLDP
----------------------------------- show lldp neighbors ----------------
Loc PortID Rem Host Name Rem Port Id Rem Chassis Id
-------------------------------------------------------------------------
Te 1/1 - TenGigabitEthernet 6/12 34:17:eb:00:20:00
---------------------------------- show control-bridge status -----------
Reason: CNU - CSP Not Up, IPE - IPC Program Error
PPE - PEM Program Error, CPE - CHM Program Error
UE - UnKnown Error
CB System MAC : 34:17:eb:00:20:00
Csp Sess Status : UP
Active CB : YES
Uplink LAG : Port-channel 257
LAG Admin Status : UP
LAG Oper Status : UP
---------------------------------
Status Reason RPM-Id PE-Id
---------------------------------
Online - 0 1
----------------------------------- show log -------------------
Syslog logging: enabled
Console logging: level debugging
Monitor logging: level debugging
Buffer logging: level debugging, 54 Messages Logged, Size (40960 bytes)
Trap logging: level informational
Sep 8 13:07:30: %PE-UNKN-UNIT1-U:CP %IRC-6-IRC_COMMUP: Link to peer
stack-unit is up
Sep 8 13:07:30: %PE-UNKN-UNIT1-U:CP %RAM-6-ELECTION_ROLE: Stack-unit 1
is transitioning to Management Stack-unit.
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %CHMGR-5-STACKUNIT_DETECTED:
stack-unit 3 present
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %POLLMGR-2-ALT_STACKUNIT_STATE:
Alternate Stack-unit is present
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %CHMGR-5-STACKUNIT_DETECTED: stack-unit
1 present
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from
stack-unit 1 (type C1048P, 52 ports)
Sep 8 13:07:31: %PE-UNKN-C1048P:1 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 60 % of the full speed
Sep 8 13:07:31: %PE-UNKN-C1048P:1 %CHMGR-2-FAN_SPEED_CHANGE: Fan speed
changed to 75 % of the full speed
Sep 8 13:07:31: %PE-UNKN-UNIT1-M:CP %RAM-5-STACKUNIT_STATE: Stack-unit 1
is in Active State.
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %IFMGR-5-ASTATE_UP: Changed interface
Admin state to up: Po 257
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-5-PEM_INSERTED: Power entry
module 0 of unit 1 is inserted
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-0-PS_UP: Power supply 0 in
unit 1 is up
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-5-PEM_REMOVED: Power entry
module 1 of unit 1 is absent
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-5-FANTRAY_INSERTED: Fan tray 0
of Unit 1 is inserted
Sep 8 13:07:32: %PE-UNKN-UNIT1-M:CP %CHMGR-4-TEMP_STATUS_CHANGE: Unit 1
temperature state changed
to 1 (Current temperature 40C).
148
Control and Monitoring