Administrator Guide

Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
Usage
Information
When the total memory utilization for a CPU exceeds the configured high/low threshold for a given time,
a threshold notification is sent as an SNMP trap. If a low threshold value is not specified, the low
threshold value is set to the same value as the high threshold value.
To return the memory thresholds to the default values, enter the no util-threshold mem all |
cp | lp slotid | pe | rp command.
Use this command in Configuration Terminal Batch mode to configure the memory utilization thresholds in
a dual-homing setup.
Example cp
Dell(conf)# util-threshold memory cp high 75 low 67
Example pe
Dell(conf)# util-threshold memory pe high 85 low 70
Related
Commands
show util-threshold memory Display the configured values of memory utilization thresholds.
show util-threshold cpu Display the configured values of CPU utilization thresholds.
virtual-ip
Configure a virtual IP address for the active management interface. You can configure virtual addresses both for IPv4 and IPv6
independently.
C9000 Series
Syntax
virtual-ip {ipv4-address | ipv6-address}
To return to the default, use the no virtual-ip {ipv4-address | ipv6-address} command.
Parameters
ipv4-address
Enter the IP address of the active management interface in a dotted decimal
format (A.B.C.D.).
ipv6-address
Enter an IPv6 address of the active management interface, in the x:x:x:x::x format.
NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Defaults none
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
162 Control and Monitoring