Administrator Guide

E-ETS Configuration TLV enabled e-ETS Configuration TLV disabled
R-ETS Recommendation TLV enabled r-ETS Recommendation TLV disabled
P-PFC Configuration TLV enabled p-PFC Configuration TLV disabled
F-Application priority for FCOE enabled f-Application Priority for FCOE disabled
I-Application priority for iSCSI enabled i-Application Priority for iSCSI disabled
----------------------------------------------------------------------------------
Interface TenGigabitEthernet 10/3
Port Role is Auto-Upstream
DCBX Operational Status is Disabled
Reason: Port Shutdown
Is Configuration Source? FALSE
Local DCBX Compatibility mode is AUTO
Local DCBX Configured mode is AUTO
Peer Operating version is Not Detected
Local DCBX TLVs Transmitted: ErPfi
Total DCBX Frames transmitted 8
Total DCBX Frames received 3
Total DCBX Frame errors 0
Total DCBX Frames unrecognized 0
Example- port
range
Dell#show interfaces tengigabitethernet 10/0-1 dcbx detail
E-ETS Configuration TLV enabled e-ETS Configuration TLV disabled
R-ETS Recommendation TLV enabled r-ETS Recommendation TLV disabled
P-PFC Configuration TLV enabled p-PFC Configuration TLV disabled
F-Application priority for FCOE enabled f-Application Priority for FCOE disabled
I-Application priority for iSCSI enabled i-Application Priority for iSCSI disabled
-----------------------------------------------------------------------------------
Interface TenGigabitEthernet 10/0
Port Role is Manual
DCBX Operational Status is Disabled
Reason: Port Shutdown
Is Configuration Source? FALSE
Local DCBX Compatibility mode is AUTO
Local DCBX Configured mode is AUTO
Peer Operating version is Not Detected
Local DCBX TLVs Transmitted: ERPfi
Total DCBX Frames transmitted 0
Total DCBX Frames received 0
Total DCBX Frame errors 0
Total DCBX Frames unrecognized 0
E-ETS Configuration TLV enabled e-ETS Configuration TLV disabled
R-ETS Recommendation TLV enabled r-ETS Recommendation TLV disabled
P-PFC Configuration TLV enabled p-PFC Configuration TLV disabled
F-Application priority for FCOE enabled f-Application Priority for FCOE disabled
I-Application priority for iSCSI enabled i-Application Priority for iSCSI disabled
-----------------------------------------------------------------------------------
Interface TenGigabitEthernet 10/1
Port Role is Manual
DCBX Operational Status is Disabled
Reason: Port Shutdown
Is Configuration Source? FALSE
Local DCBX Compatibility mode is AUTO
Local DCBX Configured mode is AUTO
Peer Operating version is Not Detected
Local DCBX TLVs Transmitted: ERPfi
Total DCBX Frames transmitted 0
Total DCBX Frames received 0
Total DCBX Frame errors 0
Total DCBX Frames unrecognized 0
Data Center Bridging (DCB)
555