Administrator Guide

Debugging and Diagnostics
Use the debugging and diagnostics commands described in this chapter to troubleshoot switch operation.
This chapter contains the following sections:
Offline Diagnostic Commands
Hardware Commands
Topics:
Offline Diagnostic Commands
Hardware Commands
Offline Diagnostic Commands
Use the offline diagnostics test suite to isolate faults and debug switch hardware. While tests are running, the system results
are saved as a text file in the flash directory: TestReport-N.txt , where N is 0,1, or 2 for the line-card processor (LP) and 0 for
the Control processor (CP) and Route Processor (RP). To display the system results in this text file, use the show file
command.
Important Points to Remember
Offline diagnostics can only be run when the unit is offline.
You can only run offline diagnostics on a unit to which you are connected via the console. In other words, you cannot run
diagnostics on a unit to which you are connected to via a stacking link.
Diagnostic results are printed to the screen. The Dell Networking OS does not write them to memory.
Diagnostics only test connectivity, not the entire data path.
diag
Run offline diagnostics on all CPUs or on a specified CPU in the switch.
C9000 Series
Syntax
diag {cp-unit | linecard | pe [pe-id stack-unit unit-number] | system} }
[alllevels | level0 | level1 | level2] [interactive] [testname name]
[terminate]
Parameters
cp
unit-id
Enter the cp unit-id parameters to run offline diagnostic tests only on the
Control Processor CPU. The Control Processor CPU ID is 0.
linecard
slot-id
Enter the linecard unit-id parameters to run offline diagnostic tests only on
a specified line card. The linecard slot-id range is from 0 to 11. Each line-card CPU
processes packets on the corresponding switch line card; for example, line-card
CPU 1 processes packets on line card 1.
pe
pe-id
Enter the pe pe-id parameters to run offline diagnostic tests only on a specified
port extender unit. The PE ID range is from 0 to 255.
NOTE: The pe option is only available when the feature extended bridge is
enabled.
12
Debugging and Diagnostics 575