all Enter the keyword all to display all the alarms corresponding to both the controlling
bridge as well as all the PEs checked into it.
Command Modes
EXEC
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.13(0.0) Introduced the keyword all on the C9010.
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series Original command.
Examples
DellEMC#show alarms
-- Minor Alarms --
Alarm Type Duration
---------------------------------------------------------------------------
No minor alarms
-- Major Alarms --
Alarm Type Duration
---------------------------------------------------------------------------
PEM 0 in unit 0 down 25 sec
PEM 2 in unit 0 down 6 sec
DellEMC#show alarm threshold
-- Temperature Limits (deg C) --
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard0 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard1 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard2 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard3 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard4 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard5 78 99 84 105 110
---------------------------------------------------------------------------
Minor Off Minor Major Off Major Shutdown
linecard6 78 99 84 105 110
---------------------------------------------------------------------------
Control and Monitoring