Administrator Guide

Starting test: psuVoltageTest ......
PSU[0] Voltage Test FAIL
PSU[1] Voltage Test FAIL
PSU[2] Voltage Test FAIL
psuVoltageTest .............................................. FAIL
rtcTest ..................................................... PASS
sataSsdTest ................................................. PASS
Starting test: showTemperature ......
+Board First Thermal Monitor Sensor[0] is 38.0 C
+Board First Thermal Monitor Sensor[1] is 33.0 C
+Board First Thermal Monitor Sensor[2] is 31.0 C
+Board First Thermal Monitor Sensor[3] is 38.0 C
+Board First Thermal Monitor Sensor[4] is 34.0 C
+Board Second Thermal Monitor Sensor[0] is 40.0 C
+Board Second Thermal Monitor Sensor[1] is 45.0 C
+Board Second Thermal Monitor Sensor[2] is 36.0 C
+Board Second Thermal Monitor Sensor[3] is 34.0 C
+Board Second Thermal Monitor Sensor[4] is 35.0 C
Sensor Temperature : 27 c
Sensor Temperature : 31 c
DDR Temperature 33 c
showTemperature ............................................. PASS
Starting test: slotInfoTest ......RPM Slot No 0
slotInfoTest ................................................ PASS
spiFlashAccessTest .......................................... PASS
Starting test: udfAccessTest ......
+ Access Test for unit 0 : PASSED
udfAccessTest ............................................... PASS
Starting test: usbTest ......
-USB "/dev/rsd0d" is not plugged/mounted/formatted; test SKIPPED
usbTest ..................................................... FAIL
LEVEL 1 DIAGNOSTIC
cpldRWTest .................................................. PASS
extCPLDRWTest ............................................... PASS
fanCntrlAccessTest .......................................... PASS
Starting test: fanCntrlSpeedTest ......
ERROR: Tray[0] fan[0] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 0 Controller Speed Test FAIL
ERROR: Tray[0] fan[1] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 1 Controller Speed Test FAIL
ERROR: Tray[0] fan[2] speed 56% is out of expected range [80-100%]
ERROR: Tray[0] fan[2] speed 41% is out of expected range [50-70%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 2 Controller Speed Test FAIL
ERROR: Tray[0] fan[3] speed 56% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[0]
FAN TRAY[0] FAN 3 Controller Speed Test FAIL
ERROR: Tray[1] fan[0] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 0 Controller Speed Test FAIL
ERROR: Tray[1] fan[1] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 1 Controller Speed Test FAIL
ERROR: Tray[1] fan[2] speed 56% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 2 Controller Speed Test FAIL
ERROR: Tray[1] fan[3] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[1]
FAN TRAY[1] FAN 3 Controller Speed Test FAIL
ERROR: Tray[2] fan[0] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[2]
FAN TRAY[2] FAN 0 Controller Speed Test FAIL
ERROR: Tray[2] fan[1] speed 57% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[2]
FAN TRAY[2] FAN 1 Controller Speed Test FAIL
ERROR: Tray[2] fan[2] speed 56% is out of expected range [80-100%]
ERROR: Fan speed variation failed for tray[2]
FAN TRAY[2] FAN 2 Controller Speed Test FAIL
306
Debugging and Diagnostics