Administrator Guide

*1 - - - -
100 0X0EFC00 1 2 17
FCoE Transit Configuration Example
The following illustration shows an core switch used as a FIP snooping bridge for FCoE traffic between an ENode (server blade)
and an FCF (ToR switch). The ToR switch operates as an FCF and FCoE gateway.
Figure 39. Configuration Example: FIP Snooping on an Core Switch
In this example, DCBx and PFC are enabled on the FIP snooping bridge and on the FCF ToR switch. On the FIP snooping bridge,
DCBx is configured as follows:
A server-facing port is configured for DCBx in an auto-downstream role.
An FCF-facing port is configured for DCBx in an auto-upstream or configuration-source role.
The DCBx configuration on the FCF-facing port is detected by the server-facing port and the DCB PFC configuration on both
ports is synchronized. For more information about how to configure DCBx and PFC on a port, refer to the Data Center Bridging
(DCB) chapter.
The following example shows how to configure FIP snooping on FCoE VLAN 10, on an FCF-facing port (0/50), on an ENode
server-facing port (0/1), and to configure the FIP snooping ports as tagged members of the FCoE VLAN enabled for FIP
snooping.
Example of Enabling the FIP Snooping Feature on the Switch (FIP Snooping Bridge)
Dell(conf)# feature fip-snooping