Administrator Guide

linecard 5 CPLD
linecard 5 IAP 3.2
linecard 6 FPGA 2.5
linecard 6 CPLD 2.1
linecard 6 IAP 3.2
RPM 0 FPGA 1 2.14
RPM 0 CPLD 2.6
RPM 0 FPGA 2 2.0
RPM 0 Backup FPGA 2.0
RPM 0 IAP 3.2
RPM 1 FPGA 1 2.14
RPM 1 CPLD 2.6
RPM 1 FPGA 2 2.0
RPM 1 Backup FPGA 2.0
RPM 1 IAP 3.2
PE RELEASE IMAGE INFORMATION :
---------------------------------------------------------------------
Platform Version Size ReleaseTime
C-Series:C1048P 9.9(0.0) 27132051 Sep 4 2015 09:59:54
PE BOOT IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target Checksum
boot flash 3.3.1.7 Control Processor passed
PE FPGA IMAGE INFORMATION :
---------------------------------------------------------------------
FPGA Name Version
CPLD 16
PE PoE-CONTROLLER IMAGE INFORMATION
---------------------------------------------------------------------
Type Version
PoE Controller 2.65
De-provisioning a Port Extender
To remove the provisioned configuration from a PE, follow one of the de-provisioning procedures in this section.
To de-provision a PE that is online, shut down its cascade ports and then enter the no pe provision pe-id command;
for example:
Dell(conf)# interface range te 1/0 , te 1/12
Dell(conf-if-range-te-1/0,te-1/12)# shutdown
Dell(conf-if-range-te-1/0,te-1/12)# exit
Dell(conf)# no pe provision 10
To de-provision a PE that is offline, enter the no pe pe-id command; for example:
Dell(conf)# no pe 10
To de-provision all attached PEs, disable the extended-bridge feature on the parent C9010. All attached PEs (online and
offline) are brought down. All PE configurations are removed. For example:
Dell(conf)# no feature extended-bridge
This command will disable the Extended-Bridge feature which will bring down all the
PEs and remove all the PE configs.
Proceed with Extended-Bridge feature disable? [yes/no]:yes
Scheduling PE reboots
You can schedule reboot of port extenders that are checked into the controlling bridge at a specific period of time.
Before scheduled PE reboots, you must first enable the schedule PE reboot feature.
Port Extenders (PEs)
713