Administrator Guide

Dell#import peer-config
10. The secondary PE comes online once the peer configurations are imported.
Once configured, the system starts functioning as a dual homing setup as shown in the following diagram:
Figure 110. Systems with Port Extender After setting up Dual Homing
You can configure PE 1 and PE 2 from both the systems.
Dell#configure terminal batch
Dell(conf-b)#pe provision 1
Dell(conf-b-pe-1)#cascade interface TenGigabitEthernet 0/0
Dell(conf-b-pe-1)#cascade interface TenGigabitEthernet 1/4 peer
Dell(conf-b)#commit
Dell(conf-b)#end
Dell#
Aug 11 22:54:36: %RPM0-P:CP %CLIBATCH-6-CLI_BATCH_CONFIG_COMPLETE_TRAP: Batch
configuration commit is success
Dell#show pe 1
Codes: A - Active, I - Inactive
SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 1
Status: online
System Mac: f8:b1:56:6e:20:07
PE Up Time: 00:17:15
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/0(A)
Cascade LAG: Po 258, Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
------------------------------------------------------------------------
1 online - C1048P f8:b1:56:6e:20:07 52
Dell#
On the VLT peer:
Dell#show pe 1
Codes: A - Active, I - Inactive
718
Port Extenders (PEs)