!!!!!!Sep 7 19:20:23: %RPM0-P:CP %DOWNLOAD-6-UPGRADE: PE 0 manual upgrade result -
upgrade success.
!!!!!
Bootflash image upgrade for all cards completed successfully.
Warning: Kindly save the system configuration before reloading.
Dell#
2. Use the upgrade system-image all command to upgrade the image in both the CB and the PE.
Dell#upgrade system-image all ftp: B:
Address or name of remote host []: 10.16.127.141
Source file name []: $w/Releases/E9.9.0/E9.9.0.0/FTOS-C9000-9.9.0.0.bin
User name to login remote host: admin
Password to login remote
host: !!!!!!!!!!!!!!!
Sep 6 19:16:06: %RPM0-P:CP %KERN-6-INT: CP Mgmt port receiving excessive traffic;
will be rate controlled
- repeated 6 times
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Sep 6 19:16:58: %RPM0-P:CP %KERN-6-
INT: CP Mgmt port receiving excessive traffic; will be rate controlled
- repeated 12 times
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Sep 6 19:17:27: %RPM0-P:CP %KERN-6-INT: CP CPU receiving
excessive Management traffic: rx is suspended
!....!!!!Sep 6 19:17:36: %RPM0-P:CP %KERN-6-INT: CP Mgmt port receiving excessive
traffic; will be rate controlled
!!.........................!..........................................................
..........
Image upgraded to CP.
!!!!!!!!!!!!!!%PE200-UNIT2-M:CP %DOWNLOAD-6-UPGRADE: Upgrade request received from
Controlling Bridge.
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!Apr 3 08:47:20: %RPM1-P:CP %DOWNLOAD-6-UPGRADE: PE 200 manual
upgrade result - upgrade success.
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
PE (200) Image upgraded successfully.
Image upgraded to RP, Standby RPM and all linecards.
3. Use the reload pe option to reload both CB and PE.
The above procedure brings up the devices in Dell Networking OS 9.10(0.0). To get a dual homing setup, you need to have a
VLT domain running in two systems with the same OS version. Refer to Setting up Dual Homing.
When you upgrade a standalone system to OS 10.0(0.0) and then connect a PE later, there might be a mismatch between
the versions. In this situation, the PE remains offline and the system displays the following:
Dell#
Apr 3 05:47:19: %RPM1-P:CP %DOWNLOAD-6-VERSION_MISMATCH_INFO: Received checkin from
PE 200. Expected version = 9-10(0-60) checkin version = 9.9(0.0)
Apr 3 05:47:20: %RPM1-P:CP %DOWNLOAD-6-UPGRADE_PROGRESS: PE 200 firmware auto sync is
in progress.
Apr 3 05:47:21: %RPM1-P:CP %BRM-5-PE_UNIT_DOWN: PE:200 Unit:2 Unit
MAC:f8:b1:56:00:02:8a is operationally down.
Apr 3 05:47:22: %RPM1-P:CP %BRM-5-BRM_LOG_PE_UNIT_VALIDATE_ERROR: PE:200 Unit:2 is in
error: SW and CAM ACL Validation error state.
Dell#show pe brief
-- Port Extenders Information --
----------------------------------------------------------
PE-id Status Stack-size Type System-MAC
----------------------------------------------------------
200 offline 1 C1048P f8:b1:56:00:02:8a
Dell#show pe 200
Codes: A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
Port Extenders (PEs)