Administrator Guide

SVC - Software Version Compatible
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present, PVE - Port Validation Error
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 10
Status: online
System Mac: 00:01:02:03:11:01
PE Up Time: 00:02:14
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/0(A),Te 1/8(I),Te 1/12(A)
Cascade LAG: Po 268(Up)
-------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
-------------------------------------------------------------------
0 online - C1048P a0:68:00:3f:92:bc 52
1 online - C1048P 6c:c0:00:11:22:33 52
2 online - C1048P 34:17:eb:00:bb:09 52
3 online - C1048P 62:74:00:41:54:c8 52
4 online - C1048P 62:74:00:41:54:c9 52
5 online - C1048P cb:28:00:42:bd:7c 52
6 online - C1048P 62:74:00:41:54:01 52
7 online - C1048P 6c:c0:00:43:11:11 52
Display summary information about the PE stack units attached to the master PE. Enter the PE ID of the master unit.
show pe pe-id system brief
Dell#show pe 255 system brief
Stack MAC : f8:b1:56:62:61:08
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
----------------------------------------------------------------------------
0 Member not present
1 Member online C1048P C1048P 9-9(0-8) 52
2 Management online C1048P C1048P 9-9(0-8) 52
3 Standby online C1048P C1048P 9-9(0-8) 52
4 Member not present
5 Member not present
6 Member not present
7 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------------------
1 0 up AC NA NA
1 1 absent NA NA
2 0 up AC NA NA
2 1 up DC NA NA
3 0 up AC NA NA
3 1 up DC NA NA
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
---------------------------------------------------------------
1 0 up up 9056 up 8888
2 0 up up 9056 up 9230
3 0 up up 10000 up 9795
Speed in RPM
Display information about a specified PE stack unit, including status, unit type, and MAC address.
Dell#show pe 255 system stack-unit 2
-- Unit 2 --
Unit Type : Management Unit
Status : online
Next Boot : online
736
Port Extender (PE) Stacking