2. Go on to the Dell Networking system and copy the software image to the flash drive, using the copy command.
3. Run the verify {md5 | sha256} [ flash://]img-file [hash-value] command. For example, verify sha256 flash://FTOS-
SE-9.5.0.0.bin
4. Compare the generated hash value to the expected hash value published on the iSupport page.
To validate the software image on the flash drive after the image has been transferred to the system, but before the image has
been installed, use the verify {md5 | sha256} [ flash://]img-file [hash-value] command in EXEC mode.
md5: MD5 message-digest algorithm
sha256: SHA256 Secure Hash Algorithm
flash: (Optional) Specifies the flash drive. The default is to use the flash drive. You can just enter the image file name.
hash-value: (Optional). Specify the relevant hash published on i-Support.
img-file: Enter the name of the Dell Networking software image file to validate
Examples: Without Entering the Hash Value for Verification
MD5
Dell# verify md5 flash://FTOS-SE-9.5.0.0.bin
MD5 hash for FTOS-SE-9.5.0.0.bin: 275ceb73a4f3118e1d6bcf7d75753459
SHA256
Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin
SHA256 hash for FTOS-SE-9.5.0.0.bin:
e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933
Examples: Entering the Hash Value for Verification
MD5
Dell# verify md5 flash://FTOS-SE-9.5.0.0.bin 275ceb73a4f3118e1d6bcf7d75753459
MD5 hash VERIFIED for FTOS-SE-9.5.0.0.bin
SHA256
Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin
e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933
SHA256 hash VERIFIED for FTOS-SE-9.5.0.0.bin
Verifying System Images on C9010 Components
Each C9010 RPM contains three components: Control Processor (CP), Route Processor (RP), and line-card processor (LP).
Each RPM component has a separate system image stored in the A: and B: flash partitions. In addition, each installed C9010 line
card has a separate image stored in partitions A: and B:.
To display the system images currently stored for all C9010 components, enter the show boot system all command. In
the command output:
Column A: lists the system images stored in flash partition A: for each RPM component. Column B: lists the system images
stored in partition B:.
The components of RPM0 installed in chassis slot 10 are:
RPM0 control processor: rmp 0 (CP)
RPM0 route processor: rmp 0 (RP)
RPM0 line-card processor: linecard 10
The components of RPM1 installed in chassis slot 11 are:
RPM1 control processor: rmp 1 (CP)
RPM1 route processor: rmp 1 (RP)
Switch Management
79